Touch display and LED functions of PosCon 3D

Display modes

Edge, width or gap; with the intuitive touch display you can easily select the right function as well as the mode for your application. The values are displayed in millimeters, no external software is required.

LEDs on the sensor

LED

Lights up

Flashes

Yellow

out1 activated

Adjustable switching output1 activated

-

Red

out2 activated

Alarm or error. Object to be measured outside measuring range or invalid received signal (e.g. soiling)

Insufficient excess gain

Object just under the measuring range limit or insufficient received signal (e.g. soiling)

Green

Supply voltage

Sensor ready for operation

Short circuit
Check connection