In order to be able to design the site optimally and continuously improve it, we use cookies. Among other things, these cookies also collect data on your usage behaviour. If you do not agree, please deselect this option in the "Statistics and Marketing" field below. You can withdraw your consent informally at any time. Further information on this and your rights in connection with the integration of cookies can be found in the data protection declaration.
Mandatory
These cookies are required only to ensure the functionality of the site.
Statistic/User tracking
Storing behavioral user data for analytical purposes and statistics.
Reliable conductivity measurement with fast temperature compensation is the basis for successful cleaning cycles, optimizing the use of cleaning agents and fast, accurate phase separation.
Since temperature is one of the four main parameters, the correct temperature prevailing right at the start of the cleaning cycle saves valuable time. Temperature sensor CombiTemp® TFRH enables hygienic temperature measurement right inside the tank.
Universal level switch CleverLevel® is the perfect protection for process and environment. Safe limit detection, optionally ignoring or detecting any foam formation, prevents tanks from damage and any escape of cleaning agents into the drains.
Predictable medium availability: Flush mounted hydrostatic level measurement with CombiTemp PFMH with display, or PBMH without display ensures the availability of cleaning agent for the next batch. The high accuracy of 0,1% is unaffected by temperature changes, foam or uneven surfaces.
Installing the switch CleverLevel® directly in-line with the CIP supply pump delivers reliable signals to avoid pump damage by dry run. Unaffected by build up, media characteristics and adherence, any lack of liquid that would disturb the cleaning will safely be detected.
The calorimetric flow sensor FlexFlow® provides both information, temperature and flow rate, that are required for determining the required energy for heating the CIP system with hot water.
Two sensitive pressure sensors PP20H installed in feed and return line detect changes in the CIP loop. Leakages causing pressure drops are recognized as well as increasing pressure pointing to blockages.
Flow sensor FlexFlow® ensures that already the supply pump delivers the desired velocity. Besides that, the flow and temperature data can be used to preset the heat exchanger operation. Both help to safe time until the desired quality parameter are reached and cleaning time counts.
The flow velocity in the return line indicates whether the entire cycle was cleaned at the desired speed. Electromagnetic flow meter PF75H with 0.2% accuracy delivers best-in-class performance and reporting stability of cleaning conditions. Further it remains unaffected by any temperature changes.
To get insights whether there is sufficient water supply for the first rinse or enough space for additional final rinse water, the ultrasonic sensor UNAM measures the precise fill level up to a tank height of 6 m.
La détection de niveau sans contact avec le capteur radar haute précision RR30 garantit qu’une quantité suffisante de média est disponible pour le prochain nettoyage acide.
Solutions de NEP évolutives pour une utilisation optimale des ressources
Kit de base pour une solution d’automatisation des tâches de nettoyage simples, ou très exigeantes
4 capteurs pour une sécurité à 100 %. 2 capteurs de niveau de seuil LFBS, un CombiLyz®pour la mesure de la concentration et de la température, un PF20H pour la mesure de la vitesse d’écoulement et de la température
Réutilisation des médias et de l’énergie dans des réservoirs de stockage isolés avec contrôle du contenu
Niveau supérieur de surveillance du process de nettoyage avec une mesure séparée de la température PT20H et une mesure très précise du débit avec le capteur de débit inductif magnétique CombiFlow®
Dosage automatique des produits de nettoyage concentrés via un capteur de débit inductif magnétique PF55S MID
Traçabilité de toutes les données sur la qualité et la consommation Surveillance de la consommation d’énergie avec le capteur de débit calorimétrique FlexFlow PF20H
Le fluide de nettoyage est fourni dans la quantité et à la température correcte, ce qui réduit les temps de préparation. Mesure de niveau avec les capteurs de pression CombiPress PFMH, les capteurs radar RR30 ou les détecteurs à ultrasons UNAM.
Les capteurs de pression PP20H surveillent le circuit de nettoyage pour détecter les blocages et les fuites
Surveillance de la consommation d’énergie avec les capteurs de débit
Avec le capteur de débit FlexFlow, Arla Foods a pour la première fois obtenu une vision claire de sa consommation d’énergie dans la production de fromage blanc sur son site de Falkenberg. Outre le débit, le capteur mesure également la température du média.