Technical data
Technical data - electrical ratings
Voltage supply
  • 24/110 VAC ±10 % (50/60 Hz)
  • 230 VAC +6/-10 % (50/60 Hz)
  • 12/24 VDC ±10 %
Residual ripple
  • <48 %
Nominal frequency
  • 50 / 60 Hz
Power consumption
  • 1.8 W
  • 2 VA
Pulse ratio
  • 1:1
Service life
  • 10 million impulses
Standard DIN EN 61010‑1
  • Protection class II
  • Overvoltage category II
  • Pollution degree 2
Emitted interference
  • EN 61000-6-4
Interference immunity
  • EN 61000-6-2
Technical data - mechanical design
Display
  • White numbers on black
Number of digits
  • 5-digits with reset button
  • 7-digits without reset button
Digit height
  • 4 mm
Count mode
  • 1 impulse = 1 count
Step-by-step switching
  • Adding in 2 half steps
Measuring range
  • 99 999 and 9 999 999
Zero setting
  • Manual by reset button
Ambient temperature
  • 0...+45 °C
Storage temperature
  • -20...+70 °C
Relative humidity
  • 80 % non-condensing
Protection EN 60529
  • IP 41
Housing type
  • Built-in housing
Connection
  • Stranded wires, 300 mm long
Mounting type
  • Front panel with spring clips
Dimensions W x H x L
  • 42 x 28 x 43 mm
Cutout dimensions
  • 37 x 23 mm
Mounting depth
  • 43 mm
Weight approx.
  • 50 g
Material
  • Housing: Noryl PPO, black

Downloads
Operating Manual
Declaration of conformity

Drawings

To the top