Technical data
Performance characteristics
Process temperature
  • Refer to section "Operating conditions"
Max. flow velocity
  • 40 m/s , gases
  • 5 m/s , liquids
Pt100 accuracy class (EN 60751)
  • B (± 0.3 °C at 0 °C)
  • ± (0.3 + 0.005 × t)°C
  • A (± 0.15 °C at 0 °C)
  • ± (0.15 + 0.002 × t)°C
  • 1/3 B (± 0.1 °C at 0 °C)
  • ± 1/3 × (0.3 + 0.005 × t)°C
  • 1/6 B (± 0.05 °C at 0 °C)
  • ± 1/6 × (0.3 + 0.005 × t)°C
Pt1000 accuracy class (EN 60751)
  • B (± 0.3 °C at 0 °C)
  • ± (0.3 + 0.005 × t)°C
  • 1/3 B (± 0.1 °C at 0 °C)
  • ± 1/3 × (0.3 + 0.005 × t)°C
Thermal response time, T50
  • ≤ 1.5 s , Ø4 mm
  • ≤ 6.1 s , Ø6 mm
  • ≤ 7.6 s , Ø8 mm
  • ≤ 13.6 s , Ø8 mm with insert
  • ≤ 11.1 s , Ø10 mm
  • ≤ 28.1 s , Ø10 mm with insert
Process pressure
  • Refer to section "Operating conditions"
Process connection
Sensor length
  • 20 … 3000 mm
Sensor tube material
  • AISI 316L (1.4404)
Surface roughness wetted parts
  • Ra ≤ 0.8 µm
Ambient conditions
Degree of protection (EN 60529)
  • IP 65
Humidity
  • ≤ 100 % RH , condensing
Vibration (sinusoidal) (EN 60068-2-6)
  • 1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / min.
Output signal
Without transmitter
  • 1 x Pt100, 2-wire
  • 1 x Pt100, 4-wire
  • 2 x Pt100, 2-wire
  • 1 x Pt1000, 2-wire
With transmitter
  • 4 … 20 mA , 2-wire
  • 4 … 20 mA , 2-wire + HART®
Compliance and approvals
EMC
  • EN 61326-1
Railway applications
  • EN 50155
Explosion protection
  • ATEX II 1 G Ex ia IIC T6...T4
  • IECEx Ex ia IIC T6...T4
  • ATEX II 3 G Ex ec IIC T5
  • Ex ia Simple apparatus, gas and dust

Software
Software

Downloads
Data sheet
Operating Manual
Certificates / approvals
Technical Reports / White Paper
CAD

Drawings
Drawings

With embedded sensor

(png | 191 KB)

With cable sensor insert

(png | 144 KB)

With DIN 43762 insert

(png | 145 KB)

With insert DIN 43762, no immersion tube

(png | 131 KB)

DIN Form B housing

(png | 70 KB)

DIN Form B housing, dual transmitter

(png | 107 KB)

Cooling neck

(png | 17 KB)

Without thread (BCID: T65)

(png | 13 KB)
The selected altAttribute does not exist!

G 1/2 A DIN 3852-A (BCID: G44)

(png | 16 KB)
The selected altAttribute does not exist!

R 1/2 ISO 7/1 (BCID: R01)

(png | 12 KB)
The selected altAttribute does not exist!

M18 × 1.5 ISO 261 / ISO 965 (BCID: M07)

(png | 12 KB)
The selected altAttribute does not exist!

M20 × 1.5 ISO 261 / ISO 965 (BCID: M08)

(png | 21 KB)
The selected altAttribute does not exist!

1/2-14 NPT (BCID: N02)

(png | 26 KB)
The selected altAttribute does not exist!

Rotating female union G 1/2 A ISO 228-1 (BCID: G23)

(png | 24 KB)
The selected altAttribute does not exist!

Rotating female union G 3/4 A ISO 228-1 (BCID: G24)

(png | 26 KB)
The selected altAttribute does not exist!

Rotating male nipple G 1/2 A ISO 228-1 (G06)

(png | 24 KB)
The selected altAttribute does not exist!

Rotating male nipple G 3/4 A ISO 228-1 (G10)

(png | 25 KB)
The selected altAttribute does not exist!

Rotating male nipple G 1 A ISO 228-1 (G11)

(png | 14 KB)

Standard response tip

(png | 35 KB)

Fast response tip

(png | 21 KB)

To the top