Fiber optic sensors

  • pulsed red LED
  • PNP
  • potentiometer
  • cable, 2 m
  • -20 … 60 °C
  • IP 40

Fiber optic sensors - FVDK 66 (standard version)

  • pulsed red LED
  • PNP
  • Teach-in
  • cable, 2 m
  • -20 … 55 °C
  • IP 40
Ambient conditions
Operating temperature -20 … +60 °C -20 … +55 °C
Protection class IP 40 IP 40
Electrical data
Current consumption max. (no load) 35 mA 30 mA
Off delay 40 ms
On / off delay 1 … 5000 ms
Output circuit PNP PNP
Output current 100 mA 100 mA
Output function Light / dark operate switchable Light / dark operate switchable
Response time / release time < 0.5 ms 0.25 … 1 ms (adjustable)
Reverse polarity protection Yes Yes
Short circuit protection Yes Yes
Voltage drop Vd <1 VDC <2.1 VDC
Voltage supply range +Vs 10 … 30 VDC 10.8 … 26.4 VDC
General data
Actual range Sb (FSE 200C1002) 240 mm 340 mm
Adjustment Potentiometer Teach-in
Alignment / soiled lens indicator LED green, flashing
Light indicator LED green 2 x 4-digit display
Light source Pulsed red LED Pulsed red LED
Output indicator LED red LED yellow
Sensing distance Tw (FUE 200C1003) 70 mm 130 mm
Suppression of reciprocal influence Yes Yes
Version Small hysteresis
Wave length 680 nm 645 nm
Mechanical data
Connection types Cable, L=2 m Cable, L=2 m
Depth 60 mm 70.2 mm
Design Rectangular Rectangular
Height / length 29.7 mm 33.8 mm
Housing material Polycarbonate/ABS Polycarbonate/ABS
Width / diameter 10 mm 10 mm