Solid shaft with synchro flange |
Solid shaft with synchro flange, 1024 sinewave cycles per revolution |
|
|
|
|
Technical data - electrical ratings | ||
Approval | UL approval / E217823 | UL-Listing: E217823 |
Consumption typ. | 100 mA (5 VDC, w/o load) | |
Consumption w/o load | ≤70 mA | |
Emitted interference | EN 61000-6-3 | EN 61000-6-4 |
Interference immunity | EN 61000-6-2 | EN 61000-6-2 |
Output frequency | ≤160 kHz | ≤180 kHz (-3 dB) |
Output signals | A 90° B, N + inverted | A+, B+, R+, A-, B-, R- |
Output stages | SinCos 1 Vpp | SinCos 1 Vpp |
Phase shift | 90 ° ±10° | |
Reference signal | Zero pulse, width 90° | |
Reverse polarity protection | Yes | |
Sensing method | Optical | Optical |
Short-circuit proof | Yes | |
Sinewave cycles per revolution | 1000 … 5000 | 1024 |
Voltage supply | 5 VDC ±5 % | 5 VDC ±5 % |
Technical data - mechanical design | ||
Admitted shaft load | ≤10 N axial ≤20 N radial |
≤40 N axial ≤80 N radial |
Connection | Connector M23, 12-pin Cable 2 m |
Connector M12, 8-pin, flexible |
Flange | Synchro flange | Synchro flange |
Material | Housing: steel Housing: steel (connection -A) Flange: aluminium |
Housing: aluminium Solid shaft: stainless steel |
Operating speed | ≤12000 rpm (IP 42) ≤6000 rpm (IP 65) |
≤6000 rpm (+25 °C) |
Operating temperature | -20...+85 °C | -25...+100 °C (see general information) |
Operating torque typ. | 0.0023 Nm (IP 42) 0.026 Nm (IP 65) |
|
Protection EN 60529 | IP 65 IP 42 |
IP 54 (flange side) IP 65 (housing side) |
Relative humidity | 95 % non-condensing | 95 % non-condensing |
Resistance | EN 60068-2-6 Vibration 10 g, 10-200 Hz EN 60068-2-27 Shock 50 g, 11 ms |
EN 60068-2-6 Vibration ±0.75 mm - 10-58 Hz, 20 g - 58-2000 Hz EN 60068-2-27 Shock 100 g, 11 ms |
Shaft type | ø6 mm solid shaft (synchro flange) | ø6 x 10 mm, solid shaft with flat |
Size (flange) | ø58 mm | ø58 mm |
Starting torque | ≤0.02 Nm | |
Weight approx. | 300 g | 300 g |