Technical data
Technical data - electrical ratings
Voltage supply
  • 10...30 VDC
Consumption typ.
  • 50 mA (24 VDC, w/o load)
Initializing time
  • ≤170 ms after power on
Interface
  • SSI
Function
  • Multiturn
Resolution
  • 0.1 mm/step
Linearity
  • 0.16 % full scale range
Number of steps
  • 75000 (7500 mm)
Sensing method
  • Magnetic
Code
  • Gray or binary
Inputs
  • SSI clock
  • Zero setting input
Interference immunity
  • EN 61000-6-2
Emitted interference
  • EN 61000-6-3
Technical data - mechanical design
Protection EN 60529
  • IP 65 (connector model)
  • IP 67 (cable model)
Material
  • Encoder housing: aluminium
  • Cable transducer housing: PA6 GF30
  • Cable: stainless steel cable coated with polyamide
Operating temperature
  • -40...+85 °C
Service life
  • Typ. 500 000 strokes
Measuring length
  • 7.5 m
Distance/revolution
  • 333.32 ±0.3 mm
Cable acceleration
  • ≤15 m/s²
Relative humidity
  • 95 %
Resistance
  • EN 60068-2-6
  • Vibration 10 g, 10-2000 Hz
  • EN 60068-2-27
  • Shock 50 g, 11 ms
Weight approx.
  • 900 g
Connection
  • Connector M12, 5-pin
  • Cable

Downloads
Data sheet
Brochures / Catalogs

Drawings

To the top