Technical data
General data
Mounting type
  • Flush
Special type
  • Linearized
Type
  • Distance measuring
Measuring distance Sd
  • 0 … 6 mm
Resolution
  • < 0.003 mm (High Accuracy Mode)
Repeat accuracy
  • 0.01 mm
Adjustment
  • IO-Link
Teach
  • Single point, Two point, Window
Linearity error
  • ± 25 µm (S = 0 ... 4 mm)
  • ± 60 µm (S = 0 ... 6 mm)
Temperature drift
  • ± 2 % (Full Scale; S = 0 ... 4 mm)
  • ± 3 % (Full Scale; S = 0 ... 6 mm)
Hysteresis
  • < 99 % (adjustable)
Power on indication
  • LED green
Output indicator
  • LED yellow
Electrical data
Switching frequency
  • 800 Hz
Voltage supply range +Vs
  • 8 … 36 VDC
Current consumption max. (no load)
  • 15 mA
Output circuit
  • PNP
  • Push-pull
  • IO-Link
Output current
  • < 100 mA
Short circuit protection
  • Yes
Reverse polarity protection
  • Yes
Mechanical data
Type
  • Rectangular
Housing material
  • PA 12
Dimension
  • 25 mm
Housing length
  • 52.4 mm
Connection types
  • Cable PVC 3 x 0,14, 2 m
Ambient conditions
Operating temperature
  • -25 … +75 °C
Protection class
  • IP 67
Communication interface
Interface
  • IO-Link V1.1
Baud rate
  • 230,4 kBaud (COM 3)
Cycle time
  • ≥ 0.6 ms
Process data length
  • 32 Bit
Process data structure
  • Bit 0 = SSC1 (distance)
  • Bit 1 = SSC2 (distance)
  • Bit 3 = alarm
  • Bit 4 = SSC3 (frequency)
  • Bit 5 = SSC4 (counter)
  • Bit 16-31 = 16 Bit measurement
IO-Link port type
  • Class A
Adjustable parameters
  • Measuring range
  • Switching point
  • Switching hysteresis
  • Measured value filtering
  • Time filters
  • LED status indicators
  • Output logic
  • Output circuit
  • Counter
  • Deactivate the sensor element
  • Find Me function
Additional data
  • Distance
  • Frequency
  • Operating cycles
  • Operating hours
  • Boot cycles
  • Operating voltage
  • Device temperature
  • Histograms

Downloads
Data sheet
Operating Manual
Software
3D CAD / CAE

Drawings
Dessins
Schéma de raccordement

Accessoires
Périphérie
IO-Link Master – IO-Link Master EtherNet/IP, 8-Port, IP67 – IO-Link Master PROFINET, 8-Port, IP67 – IO-Link Master PROFINET – IO-Link Master EtherNet/IP IO-Link Master PROFINET, 8-Port, IP67

Numéro d'article: 11215447

  • Suitable for field use with IP67
  • 8 flexibly assignable ports enable various control concepts
  • Interface diversity with 2x PROFINET, Modbus TCP and OPC UA
IO-Link Master – IO-Link Master EtherNet/IP, 8-Port, IP67 – IO-Link Master PROFINET, 8-Port, IP67 – IO-Link Master PROFINET – IO-Link Master EtherNet/IP IO-Link Master EtherNet/IP, 8-Port, IP67

Numéro d'article: 11215460

  • Field device with IP67
  • 8 ports for integrating the sensors for IO-Link communication or digital I/O
  • 2 EtherNet/IP interfaces
  • Supports Modbus TCP and OPC UA
IO-Link Master – IO-Link Master EtherNet/IP, 8-Port, IP20 – IO-Link Master PROFINET, 8-Port, IP20 – IO-Link Master PROFINET – IO-Link Master Ethernet/IP IO-Link Master PROFINET, 8-Port, IP20

Numéro d'article: 11215445

  • Suitable for control cabinet thanks to IP20
  • 8 flexibly assignable ports enable various control concepts
  • Interface diversity with 2x PROFINET, Modbus TCP and OPC UA
IO-Link Master – IO-Link Master EtherNet/IP, 8-Port, IP20 – IO-Link Master PROFINET, 8-Port, IP20 – IO-Link Master PROFINET – IO-Link Master Ethernet/IP IO-Link Master EtherNet/IP, 8-Port, IP20

Numéro d'article: 11215448

  • For the control cabinet with IP20
  • 8 ports for integrating the sensors for IO-Link communication or digital I/O
  • 2 EtherNet/IP interfaces
  • Supports Modbus TCP and OPC UA
     
ZTEST-ALL.ANALOG
Périphérie

Numéro d'article: 11084376

  • Sortie via l'affichage (V ou mA) ou LED (PNP/NPN)
  • Teach-in de détecteurs avec le bouton Teach intégré
  • Prise pour la connexion d'alimentation électrique (en option)
ZTOOL-ALL.TEACH
Périphérie

Numéro d'article: 10141584

USB IO-Link Master
Périphérie

Numéro d'article: 11048016

  • Integration des détecteurs IO-Link via USB
  • Alimentation (EU, KOR, USA, AUS, UK) et cable USB inclus
Périphérie – SensControl SensControl
Wireless IO-Link Master

Numéro d'article: 11214576

  • Configuration et surveillance d'équipements IO-Link en fonctionnement
  • Communication via WLAN, Bluetooth LE et IO-Link
  • Alimentation par la batterie rechargeable intégrée
  • Mobilité améliorée et facilité d'utilisation via l'application SensControl

Au sommet