Technische Daten
datos generales
Scanning range Sd
  • 3 … 150 mm
Scanning range close limit Sdc
  • 3 … 150 mm
Scanning range far limit Sde
  • 3 … 150 mm
Repeat accuracy
  • 0,5 mm
Resolution
  • < 0,3 mm
Response time ton
  • < 35 ms
Release time toff
  • < 35 ms
Temperature drift
  • < 2 % of distance to target So
Sonic frequency
  • 380 kHz
Adjustment
  • Teach-in
Alignment aid
  • Target indication flashing
Light indicator
  • Yellow LED / red LED
Datos eléctricos
Voltage supply range +Vs
  • 15 … 30 VDC
Current consumption max. (no load)
  • 35 mA
Output circuit
  • Voltage output
Output signal
  • 0 ... 10 V / 10 ... 0 V
Output current
  • < 15 mA
Residual ripple
  • < 10 % Vs
Short circuit protection
  • Yes
Reverse polarity protection
  • Yes
Mechanische Daten
Bauform
  • Quaderförmig
Gehäusematerial
  • PA 12
Material Schalldüse
  • POM
Breite / Durchmesser
  • 8,6 mm
Höhe / Länge
  • 48,8 mm
Tiefe
  • 57,7 mm
Anschlussart
  • Kabel PUR 4 x 0,08, 2 m
Umgebungsbedingungen
Arbeitstemperatur
  • 0 … +60 °C
Schutzart
  • IP 67

Downloads
Datenblatt
Kurzanleitung
3D CAD / CAE

Diagramme
Typische Schallkeule

Zeichnungen
Zeichnungen
Anschlussbild

Zubehör
Peripherie
ZTEST-ALL.ANALOG
Sensor-Testgerät analog & digital

Artikelnr.: 11084376

  • Anzeige über Display (V oder mA), bzw. LED (PNP/NPN)
  • Programmierung von Sensoren über integrierte Teach- Taste
  • Anschluss für Stecker-Netzteil (Als Zubehör erhältlich)