Version: V1.0Release Date: 2019-11-15


PP20H-D1
Vendor ID 350 (0x015e) Vendor Logo
Vendor Name Baumer Electric AG
Vendor Text www.baumer.com
Vendor URL http://www.baumer.com
Device ID 50011 (0x00c35b)
DeviceFamily PP20H
Features
Block Parameter yes
Data Storage yes
Profile Characteristic 0x0001 (Device Profile: Smart Sensor), 0x000a (Device Profile: ?Unknown?), 0x8001 (Function Class: Binary Data Channel)
Supported Access Locks Parameter: no, Data Storage: yes, Local Parameterization: no, Local User Interface: no
Communication
IO-Link Revision V1.1
Transmission Rate38400 bit/s (COM2)
Minimum Cycle Time 5 ms
SIO Mode Supported yes
M-Sequence CapabilityPREOPERATE = TYPE_1_V with 8 octets on-request data
OPERATE = TYPE_2_V with 8 octets on-request data
ISDU supported
Device Variant PP20H-D1
Description Pressure measurement for hygienic applications
Product ID PP20H-x.xxxxx.D1
Device Icon Device Icon
Device Symbol Device Symbol
Connection TypeNo connector (just the cable)
Connection Symbol Connection Symbol
Connection Description M12 Connector
- wire 1 brown; L+; +Vs
- wire 2 white; Other; Iout
- wire 3 (light) blue; L-; GND (0V)
- wire 4 black; C/Q; SW1
- wire 5 grey (slate); NC; N.C.

ProcessData id=P_PdPressurePa0 (condition V_DisplayControlValues.1 == 64)

ProcessDataIn "Pressure Data In" id=P_PdInPressurePa0

bit length: 32
data type: 32-bit Record

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit Integer Pressure
2 8 8-bit Integer Pressure Scale Exponent
3 7 Boolean SSC6 / Not used
4 3 Boolean Alarm / General
5 0 Boolean SSC1 / Pressure
Octet 0
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 15 14 13 12 11 10 9 8
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 3
bit offset 7 6 5 4 3 2 1 0
subindex 3 / / / / / / / / / / / / / / / / / / 4 / / / / / / / / / / / / 5

ProcessData id=P_PdPressurePaP1 (condition V_DisplayControlValues.1 == 65)

ProcessDataIn "Pressure Data In" id=P_PdInPressurePaP1

bit length: 32
data type: 32-bit Record

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit Integer Pressure
2 8 8-bit Integer Pressure Scale Exponent
3 7 Boolean SSC6 / Not used
4 3 Boolean Alarm / General
5 0 Boolean SSC1 / Pressure
Octet 0
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 15 14 13 12 11 10 9 8
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 3
bit offset 7 6 5 4 3 2 1 0
subindex 3 / / / / / / / / / / / / / / / / / / 4 / / / / / / / / / / / / 5

ProcessData id=P_PdPressurePaP2 (condition V_DisplayControlValues.1 == 66)

ProcessDataIn "Pressure Data In" id=P_PdInPressurePaP2

bit length: 32
data type: 32-bit Record

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit Integer Pressure
2 8 8-bit Integer Pressure Scale Exponent
3 7 Boolean SSC6 / Not used
4 3 Boolean Alarm / General
5 0 Boolean SSC1 / Pressure
Octet 0
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 15 14 13 12 11 10 9 8
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 3
bit offset 7 6 5 4 3 2 1 0
subindex 3 / / / / / / / / / / / / / / / / / / 4 / / / / / / / / / / / / 5

ProcessData id=P_PdPressurePaP3 (condition V_DisplayControlValues.1 == 67)

ProcessDataIn "Pressure Data In" id=P_PdInPressurePaP3

bit length: 32
data type: 32-bit Record

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit Integer Pressure
2 8 8-bit Integer Pressure Scale Exponent
3 7 Boolean SSC6 / Not used
4 3 Boolean Alarm / General
5 0 Boolean SSC1 / Pressure
Octet 0
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 15 14 13 12 11 10 9 8
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 3
bit offset 7 6 5 4 3 2 1 0
subindex 3 / / / / / / / / / / / / / / / / / / 4 / / / / / / / / / / / / 5

ProcessData id=P_PdPressurePaP4 (condition V_DisplayControlValues.1 == 68)

ProcessDataIn "Pressure Data In" id=P_PdInPressurePaP4

bit length: 32
data type: 32-bit Record

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit Integer Pressure
2 8 8-bit Integer Pressure Scale Exponent
3 7 Boolean SSC6 / Not used
4 3 Boolean Alarm / General
5 0 Boolean SSC1 / Pressure
Octet 0
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 15 14 13 12 11 10 9 8
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 3
bit offset 7 6 5 4 3 2 1 0
subindex 3 / / / / / / / / / / / / / / / / / / 4 / / / / / / / / / / / / 5

ProcessData id=P_PdProcessTemperatureCM1 (condition V_DisplayControlValues.1 == 143)

ProcessDataIn "Process Temperature Data In" id=P_PdInProcessTemperatureCM1

bit length: 32
data type: 32-bit Record

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit Integer Process Temperature
2 8 8-bit Integer Process Temperature Scale Exponent
3 7 Boolean SSC6 / Not used
4 3 Boolean Alarm / General
5 0 Boolean SSC1 / Pressure
Octet 0
bit offset 31 30 29 28 27 26 25 24
subindex 1
element bit 15 14 13 12 11 10 9 8
Octet 1
bit offset 23 22 21 20 19 18 17 16
subindex 1
element bit 7 6 5 4 3 2 1 0
Octet 2
bit offset 15 14 13 12 11 10 9 8
subindex 2
element bit 7 6 5 4 3 2 1 0
Octet 3
bit offset 7 6 5 4 3 2 1 0
subindex 3 / / / / / / / / / / / / / / / / / / 4 / / / / / / / / / / / / 5

Standard Variable "Direct Parameters 1" index=0 id=V_DirectParameters_1

data type: 128-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 120 8-bit UInteger ro Reserved
2 112 8-bit UInteger ro Master Cycle Time
3 104 8-bit UInteger ro Min Cycle Time
4 96 8-bit UInteger ro M-Sequence Capability
5 88 8-bit UInteger 17 ro IO-Link Version ID
6 80 8-bit UInteger ro Process Data Input Length
7 72 8-bit UInteger ro Process Data Output Length
8 64 8-bit UInteger ro Vendor ID 1
9 56 8-bit UInteger ro Vendor ID 2
10 48 8-bit UInteger ro Device ID 1
11 40 8-bit UInteger ro Device ID 2
12 32 8-bit UInteger ro Device ID 3
13 24 8-bit UInteger ro Reserved
14 16 8-bit UInteger ro Reserved
15 8 8-bit UInteger ro Reserved
16 0 8-bit UInteger 130 = Restore Factory Settings wo X Standard Command

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 2 3 4 5 6 7 8
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 9 10 11 12 13 14 15 16
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

Standard Variable "Direct Parameters 2" index=1 id=V_DirectParameters_2

data type: 128-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 120 8-bit UInteger Device Specific Parameter 1
2 112 8-bit UInteger Device Specific Parameter 2
3 104 8-bit UInteger Device Specific Parameter 3
4 96 8-bit UInteger Device Specific Parameter 4
5 88 8-bit UInteger Device Specific Parameter 5
6 80 8-bit UInteger Device Specific Parameter 6
7 72 8-bit UInteger Device Specific Parameter 7
8 64 8-bit UInteger Device Specific Parameter 8
9 56 8-bit UInteger Device Specific Parameter 9
10 48 8-bit UInteger Device Specific Parameter 10
11 40 8-bit UInteger Device Specific Parameter 11
12 32 8-bit UInteger Device Specific Parameter 12
13 24 8-bit UInteger Device Specific Parameter 13
14 16 8-bit UInteger Device Specific Parameter 14
15 8 8-bit UInteger Device Specific Parameter 15
16 0 8-bit UInteger Device Specific Parameter 16

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 2 3 4 5 6 7 8
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 9 10 11 12 13 14 15 16
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

Standard Variable "Standard Command" index=2 id=V_SystemCommand

data type: 8-bit UInteger
allowed values: 130 = Restore Factory Settings
access rights: wo
modifies other variables

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Device Access Locks" index=12 id=V_DeviceAccessLocks

data type: 16-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean Parameter (write) Access Lock
2 1 Boolean false Data Storage Lock
3 2 Boolean Local Parameterization Lock
4 3 Boolean Local User Interface Lock
Octet 0
bit offset 15 14 13 12 11 10 9 8
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 1
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / 4 3 2 1

Standard Variable "Vendor Name" index=16 id=V_VendorName

data type: 64-octet String UTF-8
default value: "Baumer Electric AG"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Vendor Text" index=17 id=V_VendorText

data type: 64-octet String UTF-8
default value: "www.baumer.com"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Product Name" index=18 id=V_ProductName

data type: 64-octet String UTF-8
default value: "PP20H-x.xxxxx.D1xx.xxxxxx.xxx"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Product ID" index=19 id=V_ProductID

data type: 64-octet String UTF-8
default value: "PP20H-x.xxxxx.D1"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Product Text" index=20 id=V_ProductText

data type: 64-octet String UTF-8
default value: "Pressure sensor"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Serial Number" index=21 id=V_SerialNumber

data type: 16-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Hardware Version" index=22 id=V_HardwareRevision

data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Firmware Version" index=23 id=V_FirmwareRevision

data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Application Specific Tag" index=24 id=V_ApplicationSpecificTag

data type: 32-octet String UTF-8
default value: "********************************"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Device Status" index=36 id=V_DeviceStatus

data type: 8-bit UInteger
allowed values: 0 = Device is OK, 1 = Maintenance required, 2 = Out of specification, 3 = Functional check, 4 = Failure, 5..255 = Reserved
access rights: ro
dynamic

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Detailed Device Status" index=37 id=V_DetailedDeviceStatus

data type: Array[1] of 3-octet OctetString (subindex access not supported)
access rights: ro
dynamic

octet 0 1 2  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 1 1 1  

Variable "Function Tag" index=25 id=V_FunctionTag

data type: 32-octet String UTF-8
default value: "********************************"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Location Tag" index=26 id=V_LocationTag

data type: 32-octet String UTF-8
default value: "********************************"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "SSC1 Parameter" index=60 id=V_SSC1_Param

data type: 64-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 32 32-bit Integer 0 Setpoint 1 Value 1, where the SSC1 changes.
2 0 32-bit Integer 0 Setpoint 2 Value 2, where the SSC1 changes.

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

Variable "SSC1 Configuration" index=61 id=V_SSC1_Config

data type: 16-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 8 8-bit UInteger 0 = Normal, 1 = Inverted 0 Logic SSC1 logic, concerning the output signal.
2 0 8-bit UInteger 3 = Two Point 3 Mode SSC1 mode, appropriate the IO-Link standard definitions.

octet 0 1  
bit offset 15 - 8 7 - 0  
subindex 1 2  
element bit 7 - 0 7 - 0  

Variable "MDC Selection" index=83 id=V_MDCSelection

data type: 8-bit Record
access rights: rw
modifies other variables

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 8-bit UInteger 1 = Pressure, 2 = Process Temperature 1 Source Process value that is shown on the MDC channel.

octet 0  
bit offset 7 - 0  
subindex 1  
element bit 7 - 0  

Variable "Part Number" index=86 id=V_PartNumber

data type: 16-octet String UTF-8
default value: "00000000"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Process Value Offset" index=105 id=V_MeasurementValueOffset

data type: 16-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 16-bit Integer 0 Pressure Offset for the pressure process value, e.g. to correct the impact of the mounting position on the measurement value.

octet 0 1  
bit offset 15 - 8 7 - 0  
subindex 1 1  
element bit 15 - 8 7 - 0  

Variable "Device Temperature" index=208 id=V_DeviceTemperature

data type: 32-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Float32 0.0 Current Internal temperature of the sensor.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "CPU Temperature" index=209 id=V_CpuTemperature

data type: 32-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Float32 0.0 Current Internal temperature of the CPU.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Operation Time" index=211 id=V_OperationTime

data type: 32-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 32-bit UInteger 0 Power-up Operation time since power-up.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Process Temperature" index=214 id=V_ProcessTemperature

data type: 32-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Float32 0.0 Current Temperature on the measurement membrane.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Ambient Pressure" index=215 id=V_AmbientPressure

data type: 32-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Float32 0.0 Current Ambient pressure around the sensor.

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 1  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Display Control Values" index=1024 id=V_DisplayControlValues

data type: 24-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 8-bit UInteger 64 = Pressure / Pascal / 0, 65 = Pressure / Pascal / 1, 66 = Pressure / Pascal / 2, 67 = Pressure / Pascal / 3, 68 = Pressure / Pascal / 4, 143 = Process Temperature / Celsius / -1 64 Selected PV Selected Process Value / Unit / Scale Exponent
2 8 8-bit UInteger 0 = Pascal / 0, 1 = Pascal / 1, 2 = Pascal / 2, 3 = Pascal / 3, 4 = Pascal / 4 0 PV "Pressure" Unit / Scale Exponent
3 0 8-bit UInteger 15 = Celsius / -1 15 PV "Process Temperature" Unit / Scale Exponent

octet 0 1 2  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 1 2 3  
element bit 7 - 0 7 - 0 7 - 0  

Variable "MDC Descriptor" index=16512 id=V_MDC_Descriptor

data type: 88-bit Record
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 56 32-bit Integer 0 Lower Limit Lower value of the measuring range.
2 24 32-bit Integer 0 Upper Limit Upper value of the measuring range.
3 8 16-bit UInteger 1001 = Celsius, 1130 = Pascal Unit Code Unit of the selected MDC source.
4 0 8-bit Integer 0 Scale Exponent Value of the exponent to the base of ten, applicable to the value of the MDC.

octet 0 1 2 3 4 5 6 7
bit offset 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24
subindex 1 1 1 1 2 2 2 2
element bit 31 - 24 23 - 16 15 - 8 7 - 0 31 - 24 23 - 16 15 - 8 7 - 0

octet 8 9 10  
bit offset 23 - 16 15 - 8 7 - 0  
subindex 3 3 4  
element bit 15 - 8 7 - 0 7 - 0  

Process Data Formatting

Formatting for Process Data id=P_PdInPressurePa0
Subindex 1: * 1 Pa Dec.0
Subindex 2:
Subindex 3:
Subindex 4:
Subindex 5:

Formatting for Process Data id=P_PdInPressurePaP1
Subindex 1: * 10 Pa Dec.0
Subindex 2:
Subindex 3:
Subindex 4:
Subindex 5:

Formatting for Process Data id=P_PdInPressurePaP2
Subindex 1: * 100 Pa Dec.0
Subindex 2:
Subindex 3:
Subindex 4:
Subindex 5:

Formatting for Process Data id=P_PdInPressurePaP3
Subindex 1: * 1000 Pa Dec.0
Subindex 2:
Subindex 3:
Subindex 4:
Subindex 5:

Formatting for Process Data id=P_PdInPressurePaP4
Subindex 1: * 10000 Pa Dec.0
Subindex 2:
Subindex 3:
Subindex 4:
Subindex 5:

Formatting for Process Data id=P_PdInProcessTemperatureCM1
Subindex 1: * 0.1 °C Dec.1
Subindex 2:
Subindex 3:
Subindex 4:
Subindex 5:

Observer Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_PartNumber
V_ProductID
V_ProductText
V_ApplicationSpecificTag
V_FunctionTag
V_LocationTag
V_SerialNumber
V_FirmwareRevision
V_HardwareRevision

Parameter Menu
Display Control Values
V_DisplayControlValues.Selected PV
V_DisplayControlValues.PV "Pressure"
V_DisplayControlValues.PV "Process Temperature"

Maintenance Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_PartNumber
V_ProductID
V_ProductText
V_ApplicationSpecificTag
V_FunctionTag
V_LocationTag
V_SerialNumber
V_FirmwareRevision
V_HardwareRevision

Parameter Menu
System Commands
V_SystemCommand, Button:=130
MDC (Measurement Data Channel) Settings
V_MDCSelection.Source
MDC Descriptor
V_MDC_Descriptor
If V_DisplayControlValues.2 = 0:
Offset Settings
V_MeasurementValueOffset.Pressure * 1 Pa, Dec.0
If V_DisplayControlValues.2 = 1:
Offset Settings
V_MeasurementValueOffset.Pressure * 10 Pa, Dec.0
If V_DisplayControlValues.2 = 2:
Offset Settings
V_MeasurementValueOffset.Pressure * 100 Pa, Dec.0
If V_DisplayControlValues.2 = 3:
Offset Settings
V_MeasurementValueOffset.Pressure * 1000 Pa, Dec.0
If V_DisplayControlValues.2 = 4:
Offset Settings
V_MeasurementValueOffset.Pressure * 10000 Pa, Dec.0
SSC1 (Sensor Switching Channel 1) Settings
If V_DisplayControlValues.2 = 0:
Setpoints
V_SSC1_Param.Setpoint 1 * 1 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 1 Pa, Dec.0
If V_DisplayControlValues.2 = 1:
Setpoints
V_SSC1_Param.Setpoint 1 * 10 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 10 Pa, Dec.0
If V_DisplayControlValues.2 = 2:
Setpoints
V_SSC1_Param.Setpoint 1 * 100 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 100 Pa, Dec.0
If V_DisplayControlValues.2 = 3:
Setpoints
V_SSC1_Param.Setpoint 1 * 1000 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 1000 Pa, Dec.0
If V_DisplayControlValues.2 = 4:
Setpoints
V_SSC1_Param.Setpoint 1 * 10000 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 10000 Pa, Dec.0
Configuration
V_SSC1_Config.Logic
V_SSC1_Config.Mode
Access Locks
V_DeviceAccessLocks
Display Control Values
V_DisplayControlValues.Selected PV
V_DisplayControlValues.PV "Pressure"
V_DisplayControlValues.PV "Process Temperature"

Diagnosis Menu
V_DeviceStatus
Detailed Device Status
V_DetailedDeviceStatus
Device Temperature
V_DeviceTemperature.Current °C, Dec.1
CPU Temperature
V_CpuTemperature.Current °C, Dec.1
Process Temperature
V_ProcessTemperature.Current °C, Dec.1
Operation Timer
V_OperationTime.Power-up s
Ambient Pressure
V_AmbientPressure.Current Pa

Specialist Menus

Identification Menu
V_VendorName
V_VendorText
V_ProductName
V_PartNumber
V_ProductID
V_ProductText
V_ApplicationSpecificTag
V_FunctionTag
V_LocationTag
V_SerialNumber
V_FirmwareRevision
V_HardwareRevision

Parameter Menu
System Commands
V_SystemCommand, Button:=130
MDC (Measurement Data Channel) Settings
V_MDCSelection.Source
MDC Descriptor
V_MDC_Descriptor
If V_DisplayControlValues.2 = 0:
Offset Settings
V_MeasurementValueOffset.Pressure * 1 Pa, Dec.0
If V_DisplayControlValues.2 = 1:
Offset Settings
V_MeasurementValueOffset.Pressure * 10 Pa, Dec.0
If V_DisplayControlValues.2 = 2:
Offset Settings
V_MeasurementValueOffset.Pressure * 100 Pa, Dec.0
If V_DisplayControlValues.2 = 3:
Offset Settings
V_MeasurementValueOffset.Pressure * 1000 Pa, Dec.0
If V_DisplayControlValues.2 = 4:
Offset Settings
V_MeasurementValueOffset.Pressure * 10000 Pa, Dec.0
SSC1 (Sensor Switching Channel 1) Settings
If V_DisplayControlValues.2 = 0:
Setpoints
V_SSC1_Param.Setpoint 1 * 1 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 1 Pa, Dec.0
If V_DisplayControlValues.2 = 1:
Setpoints
V_SSC1_Param.Setpoint 1 * 10 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 10 Pa, Dec.0
If V_DisplayControlValues.2 = 2:
Setpoints
V_SSC1_Param.Setpoint 1 * 100 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 100 Pa, Dec.0
If V_DisplayControlValues.2 = 3:
Setpoints
V_SSC1_Param.Setpoint 1 * 1000 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 1000 Pa, Dec.0
If V_DisplayControlValues.2 = 4:
Setpoints
V_SSC1_Param.Setpoint 1 * 10000 Pa, Dec.0
V_SSC1_Param.Setpoint 2 * 10000 Pa, Dec.0
Configuration
V_SSC1_Config.Logic
V_SSC1_Config.Mode
Access Locks
V_DeviceAccessLocks
Display Control Values
V_DisplayControlValues.Selected PV
V_DisplayControlValues.PV "Pressure"
V_DisplayControlValues.PV "Process Temperature"

Diagnosis Menu
V_DeviceStatus
Detailed Device Status
V_DetailedDeviceStatus
Device Temperature
V_DeviceTemperature.Current °C, Dec.1
CPU Temperature
V_CpuTemperature.Current °C, Dec.1
Process Temperature
V_ProcessTemperature.Current °C, Dec.1
Operation Timer
V_OperationTime.Power-up s
Ambient Pressure
V_AmbientPressure.Current Pa