• Bridge amplifier for 2 x 1/4 S/G bridge
  • Current output
  • Protection class IP 65

Measuring amplifier for 1-1 replacement of DABI AD2T-2Q

  • For Strain Rings DSRC
  • Current output
Compliance and approvals
Conformity CE
UL
Electrical data
Current consumption < 40 mA
Cut-off frequency (3 db) 1000 Hz
Reverse polarity protection Yes
Short circuit protection Yes
Supply voltage 18 ... 30 VDC
Zero adjustment active > 5 VDC
Zero adjustment inactive < 1 VDC
Zero adjustment pulse > 1 ms
Zero adjustment time < 30 ms
Electrical data bridge
Bridge resistance ≥ 350 Ω
Power supply 2.5 VDC
Signal area 500 μm/m
Environmental conditions
Operating temperature range -40 ... 85 °C
Protection class EN 60529, ISO20653 IP 65
Random IEC 60068-2-64 20 ... 1000 Hz: 0.1 g²/Hz
Shock IEC 60068-2-27 50 g / 11 ms, 100 g / 6 ms
Storage temperature range -40 ... 85 °C
Vibration IEC 60068-2-6 10 … 57 Hz: 1.5 mm p-p, 58 ... 2000 Hz: 10 g
General data
Non-linearity < 0.04 %
Output signal 4 ... 20 mA
Repeatability < 0.01 %
Zero point deviation < 0.2 %
Mechanical data
Electrical connection on control side M12, 5 pin, male
Electrical connection on sensor side M9, 4 pin, female
Material housing Aluminium, 6060, chem. passivated