Technical data
general data
special type
  • liquid level sensor for wastewater
nominal sensing distance Sn
  • 0,1 mm
mounting type
  • non-flush
GND electrode
  • no
temperature drift
  • ± 20 %
sensitivity adjustment
  • no
output indicator
  • LED yellow
measurement type
  • contact with medium
field of application
detection of non-conductive media
  • no
fill level detection through container
  • no
liquids in direct contact
  • yes
object detection / bulk goods
  • no
electrical data
voltage supply range +Vs
  • 10 … 30 VDC
current consumption max. (no load)
  • 12 mA
output circuit
  • PNP make function (NO)
output current
  • < 200 mA
voltage drop Vd
  • < 2,5 VDC
switching frequency
  • < 15 Hz
short circuit protection
  • yes
reverse polarity protection
  • yes
mechanical data
type
  • cylindrical threaded
housing material
  • POM
material (screw nut)
  • POM
material (gasket)
  • EPDM50
dimension
  • 12 mm
housing length
  • 39,5 mm
connection types
  • flylead connector M8, L=200 mm
ambient conditions
operating temperature
  • 0 … +50 °C
protection class
  • IP 67

Downloads
3D CAD data
assembly instruction
Certificates / approvals

Drawings

dimension drawing

connection diagram


Accessories
connectors and mating connectors
ESG 32SH0200
Connector M8, 3 pin, straight, 2 m, Connectors and mating connectors

Article no.:10127785

  • connecting cable for connector type M8
  • 2 m
  • unshielded
  • suitable for flexible cable carriers
  • ATEX

ESG 32SH0500
Connector M8, 3 pin, straight, 5 m, Connectors and mating connectors

Article no.:10127787

  • connecting cable for connector type M8
  • 5 m
  • unshielded
  • suitable for flexible cable carriers
  • ATEX

ESW 31SH0200
Connector M8, 3 pin, angular, 2 m, Connectors and mating connectors

Article no.:10127794

  • connecting cable for connector type M8
  • 2 m
  • unshielded
  • suitable for flexible cable carriers
  • ATEX


To the top