Technical data
Ambient conditions
Degree of protection (EN 60529)
  • IP 55
Humidity
  • < 98 % RH , condensing
Output signal
Damping
  • 0 … 60 s
Characteristic
  • Linear or customised with max. 30 points
Output signal
  • 4 … 20 mA , 2-wire
  • 20 … 4 mA , 2-wire
Accuracy
  • < 0.025 % FSR
Step response time, T90
  • < 450 ms
Temperature drift
  • ± 0.01 %/K , max.
Load resistance
  • Rs ≤ (V DC - 7 V)/0.023 A
Resolution
  • 14 bit
Up/Down scaling limits
  • 23 mA / 3.5 mA
Ripple immunity
  • < 1 % FSR (1 Vrms, 50Hz...1kHz)
Effect of variations in supply voltage
  • 0.001 %/V
HART® interface
Properties
  • Read serial number
  • Read/Change user ID
  • Read/Change configuration
  • Read input signal value
  • Read output signal value
  • Input signal logging
  • 2-point sensor-trim
  • For more information please see ‚HART Field Device Specification‘
Protocol
  • HCF standard, Rev.7
  • including „Temperature Device Family“ commands
Compliance and approvals
EMC
  • EN 61326-1
  • DNV GL - Class A
  • EN 50121-3-2:2016
Namur
  • NE21
Explosion protection
  • ATEX II 1 G Ex ia IIC T6...T4 Ga
  • ATEX II 3G Ex ec IIC T6...T5 Gc
  • IECEx Ex ia IIC T6...T4 Ga
  • IECEx Ex ec IIC T6...T5 Gc

Software
Software

Downloads
Data sheet
Operating Manual
Software Manual
Certificates / approvals
Technical Reports / White Paper
3D CAD / CAE

Drawings
Drawings

Accessories
Accessories
Mounting aids for DIN-rail – ZPX1-004 ZPX1-004
DIN-rail mounting clip for FlexTop temperature transmitters

Article no.: 11043191

Placeholder original ZPX1-015
USB-A / USB Micro-B cable, 1.8 m

Article no.: 11203494

  • Usable for programming of FlexTop 2212 and FlexTop 2222

To the top