Technical data
General data
Output signal
  • 4 ... 20 mA
  • IO-Link
Non-linearity
  • < 0.04 %
Repeatability
  • < 0.01 %
Temperature effect zero
  • < 0.01 % / 10K
Mechanical data
Material housing
  • Aluminium, 6060, chem. passivated
Electrical connection on sensor side
  • M8, 4 pin, female
Electrical connection on control side
  • M12, 5 pin, male
Electrical data bridge
Signal area
  • ± 3.8 mV/V
Bridge resistance
  • > 350 Ω
Power supply
  • 2.5 VDC
Electrical data
Supply voltage
  • 18 ... 30 VDC
Current consumption
  • < 40 mA
Resolution ADC
  • 24 bit
Sampling rate input
  • 8 kS/s
Sampling rate output
  • 8 kS/s
Cut-off frequency (-3 db)
  • 1 kHz
SNR @0.5 mV/V
  • > 70 dB
SNR @1.0 mV/V
  • > 75 dB
SNR @2.0 mV/V
  • > 80 dB
Short circuit protection
  • Yes
Reverse polarity protection
  • Yes
Max. Output range
  • < 24 mA
Output current
  • < 100 mA
IO-Link interface
IO-Link version
  • 1.1
IO-Link port type
  • Class A
Baud rate
  • 230,4 kbaud (COM3)
Process data length
  • 32 bit
Cycle time
  • ≥ 1 ms
SIO-mode
  • Yes
Process data (cyclic)
  • Process Value
  • Scale exponent
  • SSC 1
  • SSC 2
  • Quality
  • Alarm
Adjustable data (acyclic)
  • Sensor Adjustment
  • Teach-in Offset/ Tare
  • Teach-in Sensitivity
  • Input-Filter
  • Source Analog Output
  • Analog Output Signal Adjustment
  • Analog Output Signallimits (Minimum, Maximum, Alarm)
  • Source Process Value
  • SIO1/2 Function Selection
  • SIO1/2 Input Delay
Diagnostic data (acyclic)
  • Process Value
  • Minimum Process Value
  • Maximum Process Value
  • Peak Peak Process Value
  • Sample and Hold Process Value
  • Sample and Hold Delta Process Value
  • CPU temperature
  • Physical Input Signal (mV/V)
  • Device Status
  • Detailed Device Status (up to 10 messages)
  • Operation time (since power-on)
  • Operation time (lifetime)
  • Number of Power-on Cycles (Lifetime)
  • Number of Taring Cycles (Lifetime)
Environmental conditions
Operating temperature range
  • -40 ... +85 °C
Storage temperature range
  • -40 ... +85 °C
Protection class EN 60529, ISO20653
  • IP 65
Vibration IEC 60068-2-6
  • 10 … 57 Hz: 1.5 mm p-p, 58 ... 2000 Hz: 10 g
Random IEC 60068-2-64
  • 20 ... 1000 Hz: 0.1 g²/Hz
Shock IEC 60068-2-27
  • 50 g / 11 ms, 100 g / 6 ms
Compliance and approvals
Conformity
  • CE
  • UL

Downloads
Data sheet
Installation and operating instructions
Software
3D CAD / CAE

Drawings

Drawings