Technical data
Performance characteristics
Measuring principle
  • Electromagnetic flow measurement
Max. flow velocity
  • 10 m/s
Media characteristics
  • ≥ 5 µS/cm
Measuring range, flow
  • 0 … 10 m/s
  • 0 … 1770 m3/h
Measuring range, temperature
  • According to the configuration
Min. measuring span
  • 0 … 0.72 m3/h
Hysteresis
  • 3 % o. r.
Max. measuring error
  • ± 1.0 % o. r.
  • ± 0.5 % o. r. , optional
Max. turndown ratio
  • 1 : 1000
Repeatability
  • ≤ 0.1 % o. r.
Step response time
  • ≤ 400 ms
Sampling interval
  • ≤ 200 ms
Damping
  • 0.2 … 1000 s
Ambient conditions
Degree of protection (EN 60529)
  • IP 65
  • IP 67
Compliance and approvals
EMC
  • IEC 61326-1
  • EN 61326-1

Downloads
Data sheet
Certificates / approvals
Technical Reports / White Paper
Software
3D CAD

Drawings

Drawings

EN 1092-1 & ASME B 16.5 Class 150

(png | 40 KB)

To the top