Magnetic angle sensors |
Magnetic angle sensors |
|
|
|
|
Condiciones ambientales | ||
Operating temperature | -40 … +85 °C | -40 … +85 °C |
Protection class | IP 67 | IP 67 |
Datos eléctricos | ||
Current consumption max. (no load) | 20 mA | 10 mA |
Load resistance | > 1000 Ohm | > 1000 Ohm |
Output circuit | Voltage output | Voltage output |
Output signal | 0 ... 5 VDC | 0 ... 4,3 VDC |
Response time | < 2 ms | < 4 ms |
Reverse polarity protection | No | No |
Short circuit protection | No | Yes |
Voltage supply range +Vs | 4,75 … 5,25 VDC | 4,7 … 7,5 VDC |
Datos generales | ||
Angular range | 360° linear | 360° linear |
Axial misalignment max. | 0,5 mm | 0,4 mm |
Resolution | 1,41 ° | 0,09 ° |
System accuracy | ± 0,6 % | ± 0,25 % |
Temperature drift | ± 0,1 % (Full Scale) | ± 1 % (Full Scale) |
Working distance max. | 4 mm, with magnet rotor MSFS | 5 mm, with magnet rotor MSFS |
Datos mecánicos | ||
Connection types | Connector M12 | Connector M12 |
Design | Cylindrical threaded | Cylindrical threaded |
Dimension | 18 mm | 18 mm |
Housing material | Brass nickel plated | Brass nickel plated |
Material (sensing face) | PBTP | PBTP |