Bridge Amplifiers for force sensors

  • Voltage output
  • Protection class IP 65

Measuring amplifier with voltage output and digital IO-Link interface

  • +/- 10 V voltage output
  • Analog force measurement with digital IO-Link interface
  • Individual and application-specific parameterization
Additional data Diagnostic data
Error detection
Additional functions Low pass filter
Peak value memory
Sample and hold
Two digital switching points (SSC)
Remote operation
Baud rate 230,4 kbaud (COM3)
Bridge resistance ≥ 350 Ω
Cycle time ≥ 1 ms
IO-Link port type Class A
IO-Link version 1.1
Parameterizable Process input
Unit (N, kg, µm/m) selectable
Teach-in Offset/ Tare
Correlation to known force
Analog output signal
Output range analog signal
Alarm state analog signal
Functions I/O's selectable
Power supply 2,5 VDC
Process data (cyclic) Process Value
Scale exponent
SSC 1
SSC 2
Quality
Alarm
Process data length 32 bit
SIO-mode Si
Signal area ± 3,8 mV/V
Aprobaciones y certificaciones
Conformity CE
UL
Condiciones del entorno
Operating temperature range -40 ... 85 °C
Protection class EN 60529, ISO20653 IP 65
Random IEC 60068-2-64 20 ... 1000 Hz: 0.1 g²/Hz
Shock IEC 60068-2-27 50 g / 11 ms, 100 g / 6 ms
Storage temperature range -40 ... 85 °C
Vibration IEC 60068-2-6 10 … 57 Hz: 1.5 mm p-p, 58 ... 2000 Hz: 10 g
Datos eléctricos
Current consumption < 40 mA
Cut-off frequency (3 db) 1 kHz
Max. Output range ± 11 VDC
Output current < 100 mA
Resolution ADC 24 bit
Reverse polarity protection Si
SNR @1.0 mV/V > 75 dB
Sampling rate input 8 kS/s
Sampling rate output analog 8 kS/s
Short circuit protection Si
Supply voltage 18 ... 30 VDC
Datos generales
Non-linearity < 0,01 %
Output signal ± 10 VDC ± 10 VDC
IO-Link
Repeatability < 0,01 %
Temperature effect zero < 0,01 % / 10K
Datos mecánicos
Electrical connection on control side M12, 5 pin, male
Electrical connection on sensor side M8, 4 pin, female
Material housing Aluminium, 6060, chem. passivated
Hasta la cima