• 0,5 … 40 m
  • current output / push-pull
  • qTeach / external
  • connector M12
  • -40 … 65 °C
  • IP 68/69K & proTect+
  • Large measurement range up to 80 m via IO-Link
  • IO-Link and analog output (current 4–20 mA)
  • Narrow beam reduces false object detection
  • Suitable for distance measurement in outdoor areas
  • Ideal for measurements on corner cube
Additional data Distance
Excess gain
Operating cycles
Operating hours
Boot cycles
Tensione di funzionamento
Device temperature
Histograms
Velocity
Adjustable parameters Switching point
Switching hysteresis
Measured value filtering
Campo di misurazione
Time filters
Output logic
Output circuit
Counter
Analog output characteristic
LED status indicators
Deactivate the sensor element
Find Me function
Switching window definition
Signal sensitivity
Signal selection (1. / 2. / strongest / last)
Tracking mode
Baud rate 230,4 kBaud (COM 3)
Cycle time ≥ 4 ms
IO-Link port type Class A
Interface IO-Link V1.1
Predefined preference profiles Precise (standard)
Fill level fluid (slow)
Fill level fluid (fast)
Fill level solid
Fast detection
Tracking (slow)
Tracking (standard)
Tracking (fast)
Process data length 208 Bit
Process data structure Bit 0 = SSC1 (distance)
Bit 1 = SSC2 (distance)
Bit 2 = quality
Bit 3 = alarm
Bit 5 = SSC4 (counter)
Bit 8-15 = scale factor
Bit 16-47 = 32 Bit measurement
Bit 48-207 = 5 Peak (32 Bit Daten)
Condizioni ambientali
Storage temperature -40 … +85 °C -40 … +85 °C
Temperatura d'esercizio -40 … +65 °C -40 … +65 °C
Tipo di protezione IP 68/69K & proTect+ IP 68/69K & proTect+
Dati elettrici
Caduta di tensione Vd <2,5 VDC <2,5 VDC
Circuito di uscita Current output / push-pull Current output / push-pull
Corrente assorbita max. (senza carico) 210 mA 220 mA
Funzione di commutazione NO / NC adjustable NO / NC adjustable
Output current 100 mA 100 mA
Output signal 4 ... 20 mA / 20 ... 4 mA 4 ... 20 mA / 20 ... 4 mA
Protezione da cortocircuito Si Si
Protezione dall'inversione di polarità Yes, Vs to GND Yes, Vs to GND
Switching output Push-pull Push-pull
Tensione di alimentazione +Vs 15 … 30 VDC 12 … 30 VDC
Dati generali
Adjustment qTeach / external IO-Link
Alignment aid Light indicator flashing
Aperture angle 6 ° 6 °
Approvals/certificates Ecolab
FCC / CFR-47 part 18 (USA)
EN 305 550-1 V.1.2.1 (European Union)
EN 305 550-2 V.1.2.1 (European Union)
Ecolab
FCC / CFR-47 part 15 (USA)
RSS-210 Issue 10 (Canada)
EN 305 550-1 V.1.2.1 (European Union)
EN 305 550-2 V.1.2.1 (European Union)
Band width 1 GHz 1 GHz
Carrier frequency 122 … 123 GHz 122 … 123 GHz
Hysteresis typ. 40 mm
Light indicator LED yellow LED yellow
Linearity error ± 4 mm ± 10 mm
MTTF > 126 years
Modulation type FMCW FMCW
Power on indication LED green LED green
Power-up drift Compensated after 20 min.
Range resolution 500 mm 500 mm
Release time toff < 16,4 ms < 80 ms
Repeat accuracy 1 mm 1 mm
Response time ton < 16,4 ms < 80 ms
Scanning range Sd 0,5 … 40 m 0,5 … 60 m
Scanning range close limit Sdc 0,5 … 40 m 0,5 … 60 m
Scanning range far limit Sde 0,5 … 40 m 0,5 … 60 m
Temperature drift <± 10 mm (Full Scale) <± 10 mm (Full Scale)
Transmitting power (EIRP) < +20 dBm < +20 dBm
Version 2 outputs
Dati meccanici
Connection types Connector M12 Connector M12
Design Cylindrical threaded Cylindrical threaded
Height / length 90 mm 107 mm
Housing material Stainless steel 1.4404 (V4A) Stainless steel 1.4404 (V4A)
Width / diameter 30 mm 30 mm
In alto