Blind or through hollow shaft up to ø15 mm |
With blind hollow shaft |
|
|
|
|
Technical data - electrical ratings | ||
Approval | UL approval / E63076 | UL 508 / CSA 22.2 |
Consumption w/o load | ≤30 mA (24 VDC) ≤60 mA (5 VDC) |
≤70 mA |
Duty cycle | 40…60 % | |
Emitted interference | EN 61000-6-4 | EN 61000-6-3 |
Interference immunity | EN 61000-6-2 | EN 61000-6-2 |
Output frequency | ≤150 kHz | ≤300 kHz (TTL) ≤160 kHz (HTL) |
Output signals | A 90° B, N + inverted | A+, B+, R+, A-, B-, R- |
Output stages | Linedriver/RS422 TTL Push-pull short-circuit proof |
TTL/RS422 HTL/push-pull |
Phase shift | 90 ° ±10° | |
Pulses per revolution | 5 … 2048 | 100 … 5000 |
Reference signal | Zero pulse, width 90° | Zero pulse, width 90° ±10 % |
Reverse polarity protection | Yes (4.75...30 VDC) | Yes |
Sensing method | Optical | Optical |
Short-circuit proof | Yes (HTL) Yes (TTL, max. 1 s and 1 signal) |
|
Voltage supply | 5 VDC ±10 % 4.75...30 VDC 10...30 VDC |
5 VDC ±5 % 8...30 VDC 4.75...30 VDC |
Technical data - mechanical design | ||
Connection | Cable 1 m | Flange connector M12, 8-pin Flange connector M23, 12-pin Cable |
Material | Housing: carbon-fiber reinforced polyamide | Housing: aluminium die-cast Flange: aluminium |
Operating speed | ≤6000 rpm | ≤6000 rpm (+20 °C, IP 67) ≤8000 rpm (+20 °C, IP 65) |
Operating temperature | -20...+80 °C | -40...+85 °C |
Protection EN 60529 | IP 54 | IP 65 (without shaft seal) IP 67 (with shaft seal) |
Relative humidity | 95 % non-condensing | 90 % non-condensing |
Resistance | EN 60068-2-6 Vibration 10 g, 16-2000 Hz EN 60068-2-27 Shock 200 g, 6 ms |
EN 60068-2-6 Vibration 30 g, 10-2000 Hz EN 60068-2-27 Shock 250 g, 6 ms |
Rotor moment of inertia | 60 gcm² | |
Shaft type | ø10...15 mm (blind hollow shaft) | ø8...15 mm (blind hollow shaft) ø9.52 mm (blind hollow shaft) ø12.7 mm (blind hollow shaft) |
Size (flange) | ø58 mm | ø58 mm |
Starting torque | ≤0.015 Nm (+25 °C) | ≤0.02 Nm (+20 °C, IP 65) ≤0.025 Nm (+20 °C, IP 67) |
Weight approx. | 150 g | 300 g |