XC100

  • Integrated flash controller
  • User management
  • Password protection
  • Backup & Restore function
  • Coordinate transformation
  • flexible result conjunction
  • Download VeriSens® Application Suite: www.baumer.com/vs-sw

XC700

  • PROFINET and EtherNet/IP interface integrated
  • FEX image processor
  • FEXLoc 360° part location
  • ColorFex intelligent 3D color assistant
  • Flexible result conjunction
  • VeriFlash flash controller integrated
  • VeriSens XC Tube included in delivery
  • Download VeriSens Application Suite: www.baumer.com/vs-sw
Current Imax = 800 mA at 24 V DC (permanent) (±10 %, at least ± 100 mA, at 25 °C)
Imax = 4 A at 48 V DC (pulsed) (+10/-20 %, at least ± 100 mA, at 25 °C)
Imax = 800 mA at 24 V DC (permanent) (±10 %, at least ± 100 mA, at 25 °C)
Imax = 4 A at 48 V DC (pulsed) (+10/-20 %, at least ± 100 mA, at 25 °C)
Feature comparison count contour points
contour comparison
area size
count areas
pattern comparison
color identification
color positioning
count contour points
contour comparison
brightness
contrast
area size
count areas
pattern comparison
color identification
color positioning
Flash memory size 256 Mbit Flash S29GL256P10FFI010 2000 Mbit Flash S34ML02G100BHI0000
Flash time max. 1 ms (Duty Cycle max. 1:10) max. 1 ms (Duty Cycle max. 1:10)
Geometry Portée
circle
angle
count edges
point position
Portée
circle
angle
count edges
point position
edge characteristics
Part location part location on contours
part location on edges
part location on circle
part location on text line
part location on contours
part location on edges
part location on circle
part location on text line
Voltage 12 V DC or 24 V DC (permanent)
24 V DC or 48 V DC (pulsed)
12 V DC or 24 V DC (permanent)
24 V DC or 48 V DC (pulsed)
Conditions ambiantes
Case temperature max. +50 °C
Classe de protection IP 67 (with tube) IP 67 (with tube)
Humidity 0 … 90 % (non-condensing) 0 … 90 % (non-condensing)
Mechanical shock resistance EN 60068-2-27 EN 60068-2-27
Operating temperature +5 … +55 °C @ T = measurement point +5 … +55 °C @ T = measurement point
Résistance aux vibrations IEC 60068-2-6
IEC 60068-2-64
IEC 60068-2-6
IEC 60068-2-64
Température en magasin -20 … +70 °C -20 … +70 °C
Conformité
Conformity CE
RoHS
KC (R-R-BkR-VeriSens-XC-IP)
CE
RoHS
KC (R-R-BkR-VeriSens-XC-IP)
UL recognized
Données générales
Defect image memory 8 8
Features per job 32 32
High-resolution mode max. 12 inspections per second max. 31 inspections per second
Illumination direct connection (integrated flash controller) external, available as accessory
Illumination connection as accessory direct (integrated VeriFlash® flash controller)
Lens C-mount C-mount
Number of jobs (products) ≤ 255 ≤ 255
Résolution 1280 × 960 px 1280 × 960 px
Signal processing Baumer FEX® 5.0 Baumer FEX® 4.0
Type de détecteur 1/3″ CCD, color 1/3″ CCD, color
Données mécaniques
Height 99,5 mm (without lens/tube) 99,5 mm (without lens/tube)
Matériau housing: aluminum
cover glass: PMMA
housing: aluminum
cover glass XC tube: PMMA
Poids ≤ 300 g (without lens/tube) ≤ 300 g (without lens/tube)
Profondeur 49,8 mm (without lens/tube) 49,8 mm (without lens/tube)
Width 53 mm (without lens/tube) 53 mm (without lens/tube)
Données électriques
Digital inputs 5 inputs (8 … 30 V)
trigger
job selection
external teach-in
encoders (CH-A, CH-B) 500 kHz
5 inputs
trigger
job selection
external teach-in
encoders (CH-A, CH-B) 500 kHz
Digital outputs 5 outputs (PNP)
Pass / Fail
Flash Sync
Alarm
Camera Ready
Output Enable
5 outputs
Pass / Fail
Flash Sync
Alarm
Camera Ready
Output Enable
Initial setup Ethernet (10BASE-T / 100BASE-TX) Ethernet (10BASE-T / 100BASE-TX)
Inputs 8 … 30 V (polarity protected)
Nominal voltage power supply 24 V ±25 %
Nominal voltage power supply (add-on) Class 2 according to NEC / protection class III
Nominal voltage power supply (info) The device is intended for supply from an isolated limited power source according to UL61010-1, 3rd ed cl. 9.4 or a limited energy source according to UL60950-1 or Class 2 according to NEC.
Outputs PNP Ipeak = 100 mA and Ieff = 50 mA (short-circuit proof)
Plage de tension +Vs 18 … 30 V DC
Process interface TCP/UDP (Ethernet) PROFINET (CC-A)
EtherNet/IP
TCP/UDP (Ethernet)
Puissance absorbée Typical 5 W (Imax = 1.5 A at 24 V) Max. 42 W (with I/O and lighting)
Visualization web interface configurable web interface with MultiViewer function