Technical data
Performance characteristics
Measuring range
  • -1 … 600 bar
Min. measuring span
  • 0.1 bar
Max. measuring span
  • 600 bar
Pressure type
  • Absolute
  • Relative (gauged)
Standard error of measurement (BFSL)
  • ≤ ± 0.3 % FSR
  • Including non-linearity, hysteresis and non-repeatability according BFSL
  • ≤ ± 1 % FSR , for P ≤ 1 bar and P= 600 bar
  • ≤ ± 1 % FSR , zero point error
  • ≤ ± 1 % FSR , span error P > 1 Bar
  • ≤ ± 2 % FSR , span error P ≤ 1 Bar
Temperature coefficient
  • ≤ ± 0.25 % FSR/10 K , zero point P > 1 bar
  • ≤ ± 0.6 % FSR/10 K , zero point P ≤ 1 bar
  • ≤ ± 0.15 % FSR/10 K , measuring range > 1 bar
  • ≤ ± 0.3 % FSR/10 K , measuring range ≤ 1 bar
Compensated temperature range
  • -10 … 55 °C
Long term stability
  • 0.2 % FSR/a
Rise time (10 ... 90 %)
  • ≤ 3 ms

Downloads
Data sheet
Operating Manual
Certificates / approvals
Technical Reports / White Paper

Accessories
Accessories
Accessories process sensors – ZEX-ALL.B28RD100 ZEX-ALL.B28RD100
Dual-channel safety barrier (with diode return channel)

Article no.: 11217062

  • Applicable for all Baumer Ex i 4 … 20 mA current loop sensors and Ex i LBFH/LBFI level switches
  • DIN rail mounted
  • HART compatible
  • Earthed field circuit

To the top