Magnetic angle sensors

  • Voltage output
  • Connector M12
  • -40 … 85 °C
  • IP 67
  • Please order magnet separately

Magnetic angle sensors

  • Voltage output
  • Connector M12
  • -40 … 85 °C
  • IP 67
  • Please order magnet separately
Ambient conditions
Operating temperature -40 … +85 °C -40 … +85 °C
Protection class IP 67 IP 67
Electrical data
Current consumption max. (no load) 20 mA 10 mA
Load resistance > 1000 Ohm > 1000 Ohm
Output circuit Voltage output Voltage output
Output signal 0 ... 5 VDC 0 ... 4,3 VDC
Response time < 2 ms < 4 ms
Reverse polarity protection No No
Short circuit protection No Yes
Voltage supply range +Vs 4.75 … 5.25 VDC 4.7 … 7.5 VDC
General data
Angular range 360° linear 360° linear
Axial misalignment max. 0.5 mm 0.4 mm
Resolution 1.41 ° 0.09 °
System accuracy ± 0,6 % ± 0,25 %
Temperature drift ± 0,1 % (Full Scale) ± 1 % (Full Scale)
Working distance max. 4 mm, with magnet rotor MSFS 5 mm, with magnet rotor MSFS
Mechanical data
Connection types Connector M12 Connector M12
Design Cylindrical threaded Cylindrical threaded
Dimension 18 mm 18 mm
Housing material Brass nickel plated Brass nickel plated
Material (sensing face) PBTP PBTP
To the top