• Image
  • Product name
  • measuring distance Sd
  • Beam type
  • Linearity error
  • Output signal

Filter by attributes

measuring distance Sd

Beam type

Output signal

Image Product name measuring distance Sd Beam type Linearity error Output signal
OM20-P0026.HH.YIN

Article no.: 11231074

measuring distance Sd
  • 16 … 26 mm
Beam type
  • Point
Linearity error
  • ± 0.08 % Mr
Output signal
  • 4 ... 20 mA / 2 ... 10 mA
Inquire
OM20-P0026.HH.YUN

Article no.: 11232063

measuring distance Sd
  • 16 … 26 mm
Beam type
  • Point
Linearity error
  • ± 0.08 % Mr
Output signal
  • 0 … 10 VDC / 0 … 5 VDC
Inquire
OM20-P0120.HH.YIN

Article no.: 11231078

measuring distance Sd
  • 16 … 120 mm
Beam type
  • Point
Linearity error
  • ± 0,1 % Mr , 16 … 70 mm
  • ± 0,16 % Mr
Output signal
  • 4 ... 20 mA / 2 ... 10 mA
Inquire
OM20-P0120.HH.YUN

Article no.: 11231077

measuring distance Sd
  • 16 … 120 mm
Beam type
  • Point
Linearity error
  • ± 0,1 % Mr , 16 … 70 mm
  • ± 0,16 % Mr
Output signal
  • 0 … 10 VDC / 0 … 5 VDC
Inquire
OM30-L0100.HV.YIN

Article no.: 11232058

measuring distance Sd
  • 50 … 100 mm
Beam type
  • Line
Linearity error
  • ± 0,08 % Mr
Output signal
  • 4 ... 20 mA / 2 ... 10 mA
Inquire
OM30-L0100.HV.YUN

Article no.: 11233990

measuring distance Sd
  • 50 … 100 mm
Beam type
  • Line
Linearity error
  • ± 0,08 % Mr
Output signal
  • 0 … 10 VDC / 0 … 5 VDC
Inquire
OM30-L0350.HV.YIN

Article no.: 11231079

measuring distance Sd
  • 50 … 350 mm
Beam type
  • Line
Linearity error
  • ± 0,1 % Mr , 50 ... 200 mm
  • ± 0,15 % Mr
Output signal
  • 4 ... 20 mA / 2 ... 10 mA
Inquire
OM30-L0350.HV.YUN

Article no.: 11232075

measuring distance Sd
  • 50 … 350 mm
Beam type
  • Line
Linearity error
  • ± 0,1 % Mr , 50 ... 200 mm
  • ± 0,15 % Mr
Output signal
  • 0 … 10 VDC / 0 … 5 VDC
Inquire
OM30-L0550.HV.YIN

Article no.: 11231343

measuring distance Sd
  • 50 … 550 mm
Beam type
  • Line
Linearity error
  • ± 0,23 % Mr
Output signal
  • 4 ... 20 mA / 2 ... 10 mA
Inquire
OM30-L0550.HV.YUN

Article no.: 11232078

measuring distance Sd
  • 50 … 550 mm
Beam type
  • Line
Linearity error
  • ± 0,23 % Mr
Output signal
  • 0 … 10 VDC / 0 … 5 VDC
Inquire
OM30-P0100.HV.YIN

Article no.: 11233966

measuring distance Sd
  • 50 … 100 mm
Beam type
  • Point
Linearity error
  • ± 0,08 % Mr
Output signal
  • 4 ... 20 mA / 2 ... 10 mA
Inquire
OM30-P0100.HV.YUN

Article no.: 11233967

measuring distance Sd
  • 50 … 100 mm
Beam type
  • Point
Linearity error
  • ± 0,08 % Mr
Output signal
  • 0 … 10 VDC / 0 … 5 VDC
Inquire
OM30-P0350.HV.YIN

Article no.: 11232071

measuring distance Sd
  • 50 … 350 mm
Beam type
  • Point
Linearity error
  • ± 0,1 % Mr , 50 ... 200 mm
  • ± 0,15 % Mr
Output signal
  • 4 ... 20 mA / 2 ... 10 mA
Inquire
OM30-P0350.HV.YUN

Article no.: 11232072

measuring distance Sd
  • 50 … 350 mm
Beam type
  • Point
Linearity error
  • ± 0,1 % Mr , 50 ... 200 mm
  • ± 0,15 % Mr
Output signal
  • 0 … 10 VDC / 0 … 5 VDC
Inquire
OM30-P0550.HV.YIN

Article no.: 11231082

measuring distance Sd
  • 50 … 550 mm
Beam type
  • Point
Linearity error
  • ± 0,23 % Mr
Output signal
  • 4 ... 20 mA / 2 ... 10 mA
Inquire
OM30-P0550.HV.YUN

Article no.: 11231083

measuring distance Sd
  • 50 … 550 mm
Beam type
  • Point
Linearity error
  • ± 0,23 % Mr
Output signal
  • 0 … 10 VDC / 0 … 5 VDC
Inquire

Did not find what you were looking for?

To the top