XF100

  • User management
  • Password protection
  • Backup & Restore function
  • Coordinate transformation
  • flexible result conjunction
  • Download VeriSens® Application Suite: www.baumer.com/vs-sw

XF700

  • PROFINET and EtherNet/IP interface integrated
  • FEX image processor
  • FEXLoc 360° part location
  • Flexible result conjunction
  • Download VeriSens Application Suite: www.baumer.com/vs-sw
Case temperature max. +50 °C
Conformity CE
RoHS
CE
RoHS
KC (R-REI-BkRR-VeriSens-IP)
UL
Defect image memory 32 32
Depth 38 mm 38 mm
Digital inputs 5 inputs (8 … 30 V)
trigger
job selection
external teach-in
encoders (CH-A, CH-B) 500 kHz
5 inputs
trigger
job selection
external teach-in
encoders (CH-A, CH-B) 500 kHz
Digital outputs 5 outputs (PNP)
Pass / Fail
Flash Sync
Alarm
Camera Ready
Output Enable
5 outputs
Pass / Fail
Flash Sync
Alarm
Camera Ready
Output Enable
Feature comparison count contour points
contour comparison
brightness
contrast
area size
count areas
pattern comparison
count contour points
contour comparison
brightness
contrast
area size
count areas
pattern comparison
find object positions
Features per job 32 32
Flash memory size 256 Mbit Flash S29GL256P10FFI010 2000 Mbit Flash S34ML02G100BHI0000
Geometry Distance
circle
angle
count edges
point position
edge characteristics
Distance
circle
angle
count edges
point position
edge characteristics
Height 99,5 mm 99,5 mm
High-resolution mode max. 50 inspections per second max. 50 inspections per second
High-speed mode (limited resolution) max. 100 inspections per second max. 100 inspections per second
Humidity 0 … 90 % (non-condensing) 0 … 90 % (non-condensing)
Illumination integrated, LED white integrated, LED white
Initial setup Ethernet (10BASE-T / 100BASE-TX) Ethernet (10BASE-T / 100BASE-TX)
Inputs 8 … 30 V (polarity protected)
LED class risk group 1 (low risk, EN 62471:2008) risk group 1 (low risk, EN 62471:2008)
Lens 16 mm 16 mm
Material housing: aluminum
cover glass: PMMA
housing: aluminum
cover glass: PMMA
Mechanical shock resistance EN 60068-2-27 EN 60068-2-27
Nominal voltage power supply 24 V ±25 %
Nominal voltage power supply (add-on) Class 2 according to NEC / protection class III
Nominal voltage power supply (info) The device is intended for supply from an isolated limited power source according to UL61010-1, 3rd ed cl. 9.4 or a limited energy source according to UL60950-1 or Class 2 according to NEC.
Number of jobs (products) ≤ 255 ≤ 255
Object distance max. 300 mm 300 mm
Object distance min. 70 mm 100 mm
Operating temperature +5 … +60 °C @ T = measurement point +5 … +60 °C @ T = measurement point
Outputs PNP Ipeak = 100 mA and Ieff = 50 mA (short-circuit proof)
Part location part location on contours
part location on edges
part location on circle
part location on text line
part location on contours
part location on edges
part location on circle
part location on text line
Power consumption Typical 5 W (Imax = 1 A at 24 V) Max. 18 W (with I/O)
Process interface TCP/UDP (Ethernet) PROFINET (CC-A)
EtherNet/IP
TCP/UDP (Ethernet)
Protection class IP 67 IP 67
Resolution 752 × 480 px 752 × 480 px
Sensor type 1/3″ CMOS, monochrome 1/3″ CMOS, monochrome
Signal processing Baumer FEX® 4.0 Baumer FEX® 4.0
Storage temperature -20 … +70 °C -20 … +70 °C
Vibration load IEC 60068-2-6
IEC 60068-2-64
IEC 60068-2-6
IEC 60068-2-64
Visualization web interface configurable web interface with MultiViewer function
Voltage supply range +Vs 18 … 30 V DC
Weight ≤ 250 g ≤ 250 g
Width 53 mm 53 mm
Na szczyt