• 0,5 … 40 m
  • current output / push-pull
  • qTeach / external
  • connector M12
  • -40 … 65 °C
  • IP 68/69K & proTect+
  • Large measurement range up to 80 m via IO-Link
  • IO-Link and analog output (current 4–20 mA)
  • Narrow beam reduces false object detection
  • Suitable for distance measurement in outdoor areas
  • Ideal for measurements on corner cube
Additional data Distance
Excess gain
Operating cycles
Operating hours
Boot cycles
Operating voltage
Device temperature
Histograms
Velocity
Adjustable parameters Switching point
Switching hysteresis
Measured value filtering
Measuring range
Time filters
Output logic
Output circuit
Counter
Analog output characteristic
LED status indicators
Deactivate the sensor element
Find Me function
Switching window definition
Signal sensitivity
Signal selection (1. / 2. / strongest / last)
Tracking mode
Aperture angle 6 ° 6 °
Approvals/certificates Ecolab
FCC / CFR-47 part 18 (USA)
EN 305 550-1 V.1.2.1 (European Union)
EN 305 550-2 V.1.2.1 (European Union)
Ecolab
FCC / CFR-47 part 15 (USA)
RSS-210 Issue 10 (Canada)
EN 305 550-1 V.1.2.1 (European Union)
EN 305 550-2 V.1.2.1 (European Union)
Band width 1 GHz 1 GHz
Baud rate 230,4 kBaud (COM 3)
Carrier frequency 122 … 123 GHz 122 … 123 GHz
Cycle time ≥ 4 ms
Czas odpowiedzi ton < 16,4 ms < 80 ms
Czas zwolnienia toff < 16,4 ms < 80 ms
Dolny zakres pomiaru Sdc 0,5 … 40 m 0,5 … 60 m
Dryf temperaturowy <± 10 mm (Full Scale) <± 10 mm (Full Scale)
Górny zakres pomiaru Sde 0,5 … 40 m 0,5 … 60 m
Histereza typ. 40 mm
IO-Link port type Class A
Interface IO-Link V1.1
Linearity error ± 4 mm ± 10 mm
MTTF > 126 years
Materiał obudowy Stainless steel 1.4404 (V4A) Stainless steel 1.4404 (V4A)
Metoda programowania qTeach / external IO-Link
Modulation type FMCW FMCW
Obwód wyjściowy Current output / push-pull Current output / push-pull
Output function NO / NC adjustable NO / NC adjustable
Pobór prądu max. (no load) 210 mA 220 mA
Power-up drift Compensated after 20 min.
Powtarzalność 1 mm 1 mm
Predefined preference profiles Precise (standard)
Fill level fluid (slow)
Fill level fluid (fast)
Fill level solid
Fast detection
Tracking (slow)
Tracking (standard)
Tracking (fast)
Process data length 208 Bit
Process data structure Bit 0 = SSC1 (distance)
Bit 1 = SSC2 (distance)
Bit 2 = quality
Bit 3 = alarm
Bit 5 = SSC4 (counter)
Bit 8-15 = scale factor
Bit 16-47 = 32 Bit measurement
Bit 48-207 = 5 Peak (32 Bit Daten)
Prąd wyjściowy 100 mA 100 mA
Range resolution 500 mm 500 mm
Rodzaj przyłącza Connector M12 Connector M12
Spadek napięcia Vd <2,5 VDC <2,5 VDC
Stopień ochrony IP 68/69K & proTect+ IP 68/69K & proTect+
Storage temperature -40 … +85 °C -40 … +85 °C
Switching output Push-pull Push-pull
Sygnalizacja zasilania LED green LED green
Sygnalizacja świetlna LED yellow LED yellow
Sygnał wyjściowy 4 ... 20 mA / 20 ... 4 mA 4 ... 20 mA / 20 ... 4 mA
Szerokość / średnica 30 mm 30 mm
Temperatura pracy -40 … +65 °C -40 … +65 °C
Transmitting power (EIRP) < +20 dBm < +20 dBm
Typ Cylindrical threaded Cylindrical threaded
Version 2 outputs
Wspomaganie ustawienia Light indicator flashing
Wysokość 90 mm 107 mm
Zabezpieczenie przeciw zmianie polaryzacji Yes, Vs to GND Yes, Vs to GND
Zabezpieczenie przeciwzwarciowe Tak Tak
Zakres napięcia zasilania +Vs 15 … 30 VDC 12 … 30 VDC
Zakres pomiarowy Sd 0,5 … 40 m 0,5 … 60 m
Na szczyt