Bridge Amplifiers for force sensors

  • Voltage output
  • Protection class IP 65

Measuring amplifier with voltage output and digital IO-Link interface

  • +/- 10 V voltage output
  • Analog force measurement with digital IO-Link interface
  • Individual and application-specific parameterization
Additional data Diagnostic data
Error detection
Additional functions Low pass filter
Peak value memory
Sample and hold
Two digital switching points (SSC)
Remote operation
Baud rate 230,4 kbaud (COM3)
Bridge resistance ≥ 350 Ω
Conformity CE
UL
Current consumption < 40 mA
Cut-off frequency (3 db) 1 kHz
Cycle time ≥ 1 ms
Electrical connection on control side M12, 5 pin, male
Electrical connection on sensor side M8, 4 pin, female
IO-Link port type Class A
IO-Link version 1.1
Material housing Aluminium, 6060, chem. passivated
Max. Output range ± 11 VDC
Non-linearity < 0,01 %
Operating temperature range -40 ... 85 °C
Output current < 100 mA
Output signal ± 10 VDC ± 10 VDC
IO-Link
Parameterizable Process input
Unit (N, kg, µm/m) selectable
Teach-in Offset/ Tare
Correlation to known force
Analog output signal
Output range analog signal
Alarm state analog signal
Functions I/O's selectable
Power supply 2,5 VDC
Process data (cyclic) Process Value
Scale exponent
SSC 1
SSC 2
Quality
Alarm
Process data length 32 bit
Protection class EN 60529, ISO20653 IP 65
Random IEC 60068-2-64 20 ... 1000 Hz: 0.1 g²/Hz
Repeatability < 0,01 %
Resolution ADC 24 bit
Reverse polarity protection Yes
SIO-mode Yes
SNR @1.0 mV/V > 75 dB
Sampling rate input 8 kS/s
Sampling rate output analog 8 kS/s
Shock IEC 60068-2-27 50 g / 11 ms, 100 g / 6 ms
Short circuit protection Yes
Signal area ± 3,8 mV/V
Storage temperature range -40 ... 85 °C
Supply voltage 18 ... 30 VDC
Temperature effect zero < 0,01 % / 10K
Vibration IEC 60068-2-6 10 … 57 Hz: 1.5 mm p-p, 58 ... 2000 Hz: 10 g